Home > NRC Library > Document Collections > NRC Regulations (10 CFR) > Part Index > Appendix A to 10 CFR Part 20—Protection Factors for Respirators These assigned protection factors apply only in a respiratory protection program that meets the requirements of this Part. They are applicable only to airborne radiological hazards and may not be appropriate to circumstances when chemical or other respiratory hazards exist instead of, or in addition to, radioactive hazards. Selection and use of respirators for such circumstances must also comply with Department of Labor regulations. Radioactive contaminants for which the concentration values in Table 1, Column 3 of Appendix B to Part 20 are based on internal dose due to inhalation may, in addition, present external exposure hazards at higher concentrations. Under these circumstances, limitations on occupancy may have to be governed by external dose limits. Air purifying respirators with APF <100 must be equipped with particulate filters that are at least 95 percent efficient. Air purifying respirators with APF = 100 must be equipped with particulate filters that are at least 99 percent efficient. Air purifying respirators with APFs >100 must be equipped with particulate filters that are at least 99.97 percent efficient.
The licensee may apply to the Commission for the use of an APF greater than 1 for sorbent cartridges as protection against airborne radioactive gases and vapors (e.g., radioiodine). Licensees may permit individuals to use this type of respirator who have not been medically screened or fit tested on the device provided that no credit be taken for their use in estimating intake or dose. It is also recognized that it is difficult to perform an effective positive or negative pressure pre-use user seal check on this type of device. All other respiratory protection program requirements listed in § 20.1703 apply. An assigned protection factor has not been assigned for these devices. However, an APF equal to 10 may be used if the licensee can demonstrate a fit factor of at least 100 by use of a validated or evaluated, qualitative or quantitative fit test.No distinction is made in this Appendix between elastomeric half-masks with replaceable cartridges and those designed with the filter medium as an integral part of the facepiece (e.g., disposable or reusable disposable).
Both types are acceptable so long as the seal area of the latter contains some substantial type of seal-enhancing material such as rubber or plastic, the two or more suspension straps are adjustable, the filter medium is at least 95 percent efficient and all other requirements of this Part are met. The assigned protection factors for gases and vapors are not applicable to radioactive contaminants that present an absorption or submersion hazard. For tritium oxide vapor, approximately one-third of the intake occurs by absorption through the skin so that an overall protection factor of 3 is appropriate when atmosphere-supplying respirators are used to protect against tritium oxide. Exposure to radioactive noble gases is not considered a significant respiratory hazard, and protective actions for these contaminants should be based on external (submersion) dose considerations. No NIOSH approval schedule is currently available for atmosphere supplying suits. This equipment may be used in an acceptable respiratory protection program as long as all the other minimum program requirements, with the exception of fit testing, are met (i.e., § 20.1703).
The licensee should implement institutional controls to assure that these devices are not used in areas immediately dangerous to life or health (IDLH). This type of respirator may be used as an emergency device in unknown concentrations for protection against inhalation hazards. new mattress smell air purifierExternal radiation hazards and other limitations to permitted exposure such as skin absorption shall be taken into account in these circumstances. air purifying respirator protection factorThis device may not be used by any individual who experiences perceptible outward leakage of breathing gas while wearing the device.dryer air duct cleaner [64 FR 54558, Oct. 7, 1999; 64 FR 55524, Oct. 13, 1999]Cohen HJ1, Hecker LH, Mattheis DK, Johnson JS, Biermann AH, Foote KL.
Author information1University of New Haven, Department of Occupational Safety and Health, West Haven, CT 06516, USA.AbstractA study protocol was developed to obtain simulated workplace protection factor (SWPF) data for eleven models of powered air-purifying respirators (PAPRs) and supplied-air respirators (SAR) with hoods and helmets. Respirators were tested in a chamber that allowed the simulation of 12 exercises, including 2 exercises of interest to the pharmaceutical industry. Each respirator was tested by 12 volunteers, and a total of 144 sets of test results were obtained for each device. The testing protocol allowed SWPFs up to 250,000 to be measured (limit of quantification). Median SWPFs for all respirators, except one SAR, were at or above this reporting limit. Lower fifth percentiles were above 100,000, except for one SAR previously noted. An assigned protection factor (APF) was estimated for each respirator by dividing the lower fifth percentile by a safety factor of 25. APFs ranged from 6000-10,000 for PAPRs (including one loose-fitting PAPR) and 3400-10,000 for SARs, with one exception.
This SAR had a lower fifth percentile of less than 20 and an estimated APF of 1. Results indicated that most respirators tested could provide a high degree of protection for workers, although one National Institute for Occupational Safety and Health-approved SAR provided minimal, if any, protection. Direct testing in a simulated workplace seems the only method that will assure employers of choosing an adequate SAR. This may be true for other classes of respirators. Furthermore, the historical approach of establishing APFs for classes of respirators, rather than individual models, may not provide adequate protection to the wearer. This is also a serious problem for regulatory agencies seeking to promulgate respirator standard provisions such as APFs for classes of respirators.PMID: 11669385 [PubMed - indexed for MEDLINE] Publication TypesComparative StudyResearch Support, Non-U.S. Gov'tMeSH TermsAdultAerosols/analysisAir Pollutants, Occupational*Equipment DesignFemaleHumansMaleMiddle AgedModels, Theoretical*Occupational Exposure/prevention & control*Occupational Exposure/standards*Photometry/standardsReference ValuesRespiratory Protective Devices/standards*Sensitivity and SpecificitySubstancesAerosolsAir Pollutants, OccupationalOther Literature SourcesCOS Scholar UniverseMedicalOccupational Health - MedlinePlus Health InformationMiscellaneousNCI CPTAC Assay Portal