air intake cleaning for whirlpool heaters

IP address: 54.190.220.233Time: 2016-09-25T15:37:03ZURL: http://www.youtube.be/watch%3Fv%3DB7Lz8vbNMjQ The pilot light went out on my gas water heater. I followed the instructions and had it lit three times now for about 15 minutes each time but it wont stay lit. Not sure what to do at this point? It could be that the Thermocouple has failed or is failing. This would cause the system to think there is no flame present, and shut off the gas supply for safety (so it doesn't fill the house with gas). If you don't feel comfortable working on the heater; or you don't have the knowledge and/or tools to do so, call a trained professional to come take a look. There's a thermal shutoff that automatically stops the gas if the pilot light doesn't heat it up. This prevents you from leaking unburned gas into the home, which would be very bad. Check that the probe is in contact with the pilot flame. The fact that it stays on for 15 minutes makes me think this may not be the issue, but depending on the model, there may be a delay after lighting the pilot before this activates.

The next concern is a lack of ventilation. Make sure fresh air can get to the water heater. Get out the vacuum and cleanup all those cobwebs and flammable dust balls. The location of the water heater should have a fresh air supply, either with a louvered door or a vent line that goes outside. Make sure these are open. Related to a lack of ventilation is over-ventilation, or a draft that is blowing out the light. Make sure the shields are in place on the heater and that the HVAC doesn't have anything blowing directly on the hot water heater. The last thing I can think of is a lack of gas coming into the line. This could be from a valve not being all the way open. It could also be from a condensation build up in the line. There should be a small bit of pipe leading to a dead end cap pointed down somewhere after the shutoff. I suppose it's possible for this to fill up, but have never seen it myself. Whether shutting off the gas, opening this up and allowing any moisture to drain is a DIY job, I don't know, maybe someone else will comment.

I currently had this issue with my Whirlpool water heater. The problem turned out to be the gas control valve. It required removing the control valve (the front piece where you set temperature light it, etc.) It wasn't too bad to replace, but did take about 2-3 hours. You need to drain the water heater, turn off gas, etc. If it's not under warranty the part ran about $70 at Lowes. Since mine was still under warranty Whirlpool paid for it. So that's something you'll want to check in to. They have a video and pdf on the site on how to replace it. If yours isn't whirlpool I'm not sure how different it will be. Mine has worked great since I replaced it. Hope I have helped. (I should mention that they thought it was my thermocouple at first, but since it did light and would stay lit for half an hour that rules that out.) Replacing Gas Valve Video Replacing Gas Valve PDF The sealed units have a heat link underneath the gas burner. When the vents get clogged by dust and dirt, the combustion chamber overheats and the heat link melts.

Beneath the heat link is a spring clip which holds down a metal rod. What you will see when you take out the burner is a loose spring clip because it popped out when the link melted. This heat link simply holds down a metal rod that springs up and cuts off the intake air. Without intake air, your unit may light after a while but will not stay lit and will not relight until a little fresh air leaks in.
clean macbook air for sellingTo replace the link you have to contact the manufacturer who will send you one for free only one time.
spray gun cleaning brushesYou need to shove the rod back down and slip the new heat link into the slots on each side which hold it in.
portable air purifier reviews canadaYou also need to clean the air intakes on both sides of the hot water tank by using a vacuum cleaner and/or compressed air.

Then I suggest periodically repeating the cleaning process. I found a three minute video on Youtube that showed this clearly. I've read everything online about these heaters and the vids on YouTube. My theory isn't that its the thermocouple or just lack of air going in,its that these sealed water heaters don't let air OUT of the pilot light area. Pressure builds up when the burner kicks in with a small blast- blows out the pilot. If you remove that glass window..air can escape...the heater works fine. Just use some wire screen instead of glass to cover and it also keeps the pilot light from getting too large an air intake..just enough air in,and enough going out. Of course,this is all at your own risk,etc. But,c'mon water heaters worked like that for decades,and nobody complained. Sign up using Google By posting your answer, you agree to the privacy policy and terms of service.Browse other questions tagged water water-heater or ask your own question.Whirlpool hot water heaters, features, specs, model reviews

and model numbers explained. Explore the features that increase the energy waste and greenhouse gases and protect the unit. Whirlpool offers a variety of hot water heaters for including both gas-powered and electrical type. and the quality is great. For example, electric models are designed as high efficient heat pumps and standard type, which utilize several advanced features such as the 6th Sense and LCD digital display. models have only three sizes and three categories, from energy efficiency to high efficiency, plus they offer6, 9 and 12 years. Those models with the features such as the commercial-grade anode rod and self-cleaning system are found among water heaters with the longer warranties, such as 9 and 12 years. hot water heaters can use natural or propane gas. With the sizes from 30 to the most popular 50-gallon, gas heaters are ideal equally for one-bath homes to larger homes with five and more members.

are two sizes, tall, which is a standard type and short that are used homes with the space issue. The economy, cheaper models are those with 6-year warranty while the most expensive ones are gas water heaters with the 12-year warranty that include the microprocessor, system, ultra Low NOx burner, 6-th sense technology andOne of these models comes with the patented air intake system which helps in the energy factor increase up to 0.70. find more details about Whirlpool gas water heaters here. hot water heaters that are using the electricity to run can be found instandard and heat pumps. utilize the heat pump can produce hot water twice and more efficiently than conventional type, and they use the advanced technology. models include the microprocessor and the touch screen LCD display for convenient temperature control and error code display. See the review of the Whirlpool electric water heaters and how they reduce the standby heat