uv air purifier installation

In-duct Home UV Air Installing Your  American-Lights� High Output In-duct UV Air Cleaner Is A Simple Process That Can Be Performed By Most People. Click Here to print a full pdf version of our installation instructions Please observe all warnings. Disconnect the power source before removal or lamp replacement. installation procedures should have the UV lamp at a right angle to the air flow with the UV lamp centered in the duct or plenum. American-Lights In-duct UV Air Cleaner may be installed in either the supply or return sides (coil or return as needed) or yourThe benefits from your UV air purifier will be equally effective no matter which side the installation occurs.  Note, however, if UV lamp is installed close to register or grill, the ultraviolet light may cause night glow effect which may be objectionable to homeowner. SAFETY NOTICE: DO NOT LOOK DIRECTLY INTO THE UV LAMP. Procedure Of The American-Lights In-duct UV Air Cleaner:
established a convenient location for the UV Air Cleaner, drill oneair cleaner for throttle body 1.3/8� hole for the UV lamp and lock nut on coupling afterair purifier hair loss placing unit in desired location. new york air conditioning & air duct cleaningUsing cotton gloves to avoid oils on UV lamp, slide it through coupling and secure by tightening adjustable coupling to base. Avoid over tightening to prevent Plug socket to lamp. Snap air cleaner's cover in place and power air cleaner to grounded adjacent location within 6� of unit, drill a �" hole and insert the glow indicator. requires one HO-14 or HO-22 germicidal UV lamp, obtained from your High Output UV Air Cleaner is the strongest, fully certified UV
air cleaner available on the air-quality market. minimum of rules for a productive installation: direct exposure (within 24-30�) of non-UV inhibited plastics. (Including drip pans, plastic filter frames, etc.) that would permit the homeowner access to the lamp. closet door with louvers and the unit exposed when door is open or light is seen through the louvers.) The night light issue should be considered if this is being placed in less than optimum location: across top of coil @ right angles to �A�; Return plenum if not within visible range of filters etc. (You do not want this where a homeowner can remove the filter and see or advertised this High Output lamp will provide strong germicidal protection for 3 years the reason - it does not cycle on/off thereby maximizing its life and efficiency. However, to keep the UV air cleaner in top performance range, it is recommended the UV lamp to be replaced every year.
specification sheet and installation instructions will provide answers to most situations and questions. UV lamp once per year.We only carry one brand of UV in-duct air purification systems - American-Lights� - because we know that we're offering you the very best with these top-quality units. American-Lights� Air Purifiers feature:Full 2 year manufacturer's warrantyMoney back guaranteeNo filters to clean or replace - American-Lights� In-duct Home UV Air Cleaner technology oxidizes particulates rather than just filtering themCustom models available for home and commercial useUnlimited free customer support complete line of UV commercial air cleaners, whole house air cleaningPrint the UV Air Cleaner Installation Instructions Observe all warnings and cautions. complete instructions before beginning of installation. American-Lights� UV Air Cleaner must be installed by authorized and qualifiedThis fixture is designed for use with germicidal lamps and must be
installed in compliance with competent technical directions so the user's eye and bare skin will not be subjected to ultraviolet rays. NEVER expose eyes or skin to UVC light from any source. NEVER operate this unit outside of plenum. Before installing or servicing this unit, ALWAYS turn off the power supply and unplug the power cord. Electrical shock can cause personal injury or death.Do not mount in direct line-of-sight of openings in the duct or any access panels of a product connected to the duct. CAUTION: Do not mount in close proximity to plastic coated wiring regardless of their UV protective coating or in direct line-of-sight of plasticDo not mount closer than 36" from any plastic air filter (fiberglass and metal filters are safe). CAUTION: Equipment Damage Hazard. Ultraviolet light can cause color shift or surface degradation and sometimes - structural degradation of non-metallicSelect mounting location that prevents exposure to plastic
flexible duct components, polyurethane foam insulation material, rubber hoses,If mounting options are limited, items above should be protected with ultraviolet resistant material such as aluminum foil, aluminum duct tape, or metallic shields or the equivalent. FOLLOW ALL LOCAL CODES AND REGULATIONS WHEN WIRING THISDO NOT install the UV lamp close to a grill if its �night light� effect Disconnect power before removal orProper installation should have UV lamps at right angles to air flow, centered in duct or plenum. The UV Air Cleaner should be installed at least 36" away from plastic air filters. The air cleaner can be placed on either supply or return side of the coil and is equally effective. Note: if UV lamp is installed close to register or grill, the ultraviolet light may cause objectionable night glow effect. Step-by-step UV Air Cleaner Installation Instructions: UV lamp replacement: requires original American-Lights AAWHO/14 germicidal UV lamp, obtained from your
Other UV lamps are incompatible and may damage the air cleaner. Establish a location, not less than 36" from plastic air filters, for installation on the RETURN or SUPPLY SIDE of the air handlingThe best location is over the coil so UV can keep it clean of microbial contamination and growth, including mold growth. The proximity of an available power source should be also considered when selecting the mounting site. After determining the best position, remove the 2 Philips screws on the top of the cover, remove the American-Lights� cover and place the housing assembly against the exterior wall. Use it as a template for transferring the mounting holes as well as the entry holes for the UV lamp. Drill one 1" hole for the UV lamp. Mount the air cleaner chassis to the duct by fastening the self tapping screws or the longer screws for duct board. To install the UV lamp, slide the UV lamp through the hole in the unit and duct until the retaining ring will not allow further
Slide retaining clip over retaining ring and tighten the retaining clip�s fasteners so it will not move. Carefully attach the plug to the 4-pin end of the lamp. Replace the cover and tighten the screws. Do not pinch or cut any wires. Drill a 7/16� hole in the duct 6 inches away from the mounting position of the UV lamp. Insert the indicator plug in the hole. When the lamp is lit, the plug will glow as an indicator that the unit is working correctly. Attach the Warning Label on the duct next to the installed UV Air Cleaner. Power the unit � the UV lamp will come on instantly. For best results: leave the UV air cleaners ON at all times with the HVAC fan running continuously for the first 2 weeks by turning the thermostat switch to the ON position. After that the UV air cleaner should continue to stay ON but the fan can be switched to Print the UV Air Cleaner Installation Instructions UV Air Cleaner Important Tips The American-Lights� High Output UV Air Cleaner is the strongest UV air cleaner available on the indoor air-quality market in its range.